Hi,
I am not sure about record-routing in combination with failover of
drouting. Maybe someone knows for sure :)
If i got a configuration where i am record_routing on inital invite, but
later there is a failover (use_next_gw() returns true) and the call is
sent to the next gateway. But the serial forked call (second INVITE) is
missing the Record-route header?
Does this mean i just have to explicitly call record routing again on
failover? But to me it seems like this can't be right, or is this
correct/expected behaviour?
|
if (use_next_gw()) {
...
record_route();
|}
Best Regards
--