Hi,

I am not sure about record-routing in combination with failover of drouting. Maybe someone knows for sure :)

If i got a configuration where i am record_routing on inital invite, but later there is a failover (use_next_gw() returns true) and the call is sent to the next gateway. But the serial forked call (second INVITE) is missing the Record-route header?


Does this mean i just have to explicitly call record routing again on failover? But to me it seems like this can't be right, or is this correct/expected behaviour?

|

if (use_next_gw()) {
...
record_route();

|}



Best Regards

--