Hi Nick,
What will help you is a kind of route_to_gw() but instead of taking as
param a single GW, to take a list of GWs ? and to iterate through using
use_next_gw() ?
Also, what Nick Altman says is very very true - you can simply populate
the AVPs he mentioned (do it from script, loading from a DB, replacing
the functionality of do_routing() ) and do the use_next_gw() ......it
simply works....and it simply scale :)
Regards,
Bogdan-Andrei Iancu
OpenSIPS Founder and Developer
http://www.opensips-solutions.com
On 11.02.2014 21:37, Nick Cameo wrote:
On Thu, Feb 6, 2014 at 1:54 PM, Nick Altmann <[email protected]
<mailto:[email protected]>> wrote:
Carrier is just a gateways list. You may also set weight for each gw
and drouting will choose gw's due its weight.
Route_to_carrier() gets carrier parameters (gateways list) into avps
and set $ru to first gw address.
Use_next_gw() extract next gw parameters from avps and set $ru to the
new gateway.
So, you may try to work with these avps to change routing behaviour.
Hello Nick,
Thank you for your response. After looking into it further I realized
that this approach is not very scalable. The reason why
is because we have over 30 interconnects (30 gateways), and would have
to maintain all of them to the carrier table.
Is there not way to pass a gwlist list to a function dynamically (at
run time) that will route to that call with failover? do_routing
would be perfect! If it adheres to the order of the gateway list.
PS I really don't want to change the ruri in perl either if this
functionality can be made available in the script.
Kind Regards,
Nick.