Yes, it work for it, but for TCP based protocols you need (aside the
pinging) to take care of keeping the connection up (opensips may close
it if not used) - but using registrar (via save()) will take care of
this automatically.
Also look into "tcp_no_new_conn_bflag":
http://www.opensips.org/Documentation/Script-CoreParameters-1-10#toc93
Regards,
Bogdan-Andrei Iancu
OpenSIPS Founder and Developer
http://www.opensips-solutions.com
On 19.02.2014 23:19, Rudy Eschauzier wrote:
Thanks so much for looking into this!
One last question: will this approach also work with TCP & TLS?
Regards,
Rudy
I see, but doesn't that mean that the uac will need to register with OpenSips,
instead of what I am trying to do: forward registration to Asterisk?
You can do both - pass the REGISTER through (to FS) and have it also
locally registered on OpenSIPS ( use the save() function in the reply
route when you get the 200 OK for REGISTER).