Hello,
There is no other way but to use the aaa_radius module with the
radius_send_auth() (
http://www.opensips.org/html/docs/modules/1.11.x/aaa_radius.html#id293422)
and use custom input sets of RADIUS AVPs
(http://www.opensips.org/html/docs/modules/1.11.x/aaa_radius.html#id249603)
to be able to push the tech prefix to the RADIUS server.
Regards,
Bogdan-Andrei Iancu
OpenSIPS Founder and Developer
http://www.opensips-solutions.com
On 10.03.2014 18:54, Alcindo Schleder wrote:
How to authenticate customers without username and password using tech