Hi Jim,

That column is read by OpenSIPS only at startup. Basically it give OpenSIPS the starting values for the GW states. If you change the value in DB, it will have no effect on OpenSIPS until the next restart.

On the other side, OpenSIPS is able to update (write) that column if the in-memory state of the GW does change (via MI or ping detection) - but you need to be sure that 'persistent_state' is on (see http://www.opensips.org/html/docs/modules/2.4.x/drouting.html#param_persistent_state).

Regards,

Bogdan-Andrei Iancu

OpenSIPS Founder and Developer
  https://www.opensips-solutions.com
OpenSIPS Summit 2019
  https://www.opensips.org/events/Summit-2019Amsterdam/

On 01/04/2019 04:40 PM, Jim DeVito wrote:
Hi Guys,

Maybe i'm misunderstanding this column. I understand how to enable and disable a carrier via MI commands during run time. However I want to be able to modify the database (dr_carriers) state column and have that respected at next reload. Currently I can change that to 0 or 1 but the carrier is always marked as enabled when I check at run time.

I've tried with persistent_state set to 0 and 1 with no effect.

Thanks!

-------------
Jim DeVito


_______________________________________________