Hi Jim,
That column is read by OpenSIPS only at startup. Basically it give
OpenSIPS the starting values for the GW states. If you change the value
in DB, it will have no effect on OpenSIPS until the next restart.
On the other side, OpenSIPS is able to update (write) that column if the
in-memory state of the GW does change (via MI or ping detection) - but
you need to be sure that 'persistent_state' is on (see
http://www.opensips.org/html/docs/modules/2.4.x/drouting.html#param_persistent_state).
Regards,
Bogdan-Andrei Iancu
OpenSIPS Founder and Developer
https://www.opensips-solutions.com
OpenSIPS Summit 2019
https://www.opensips.org/events/Summit-2019Amsterdam/
On 01/04/2019 04:40 PM, Jim DeVito wrote:
Hi Guys,
Maybe i'm misunderstanding this column. I understand how to enable and
disable a carrier via MI commands during run time. However I want to
be able to modify the database (dr_carriers) state column and have
that respected at next reload. Currently I can change that to 0 or 1
but the carrier is always marked as enabled when I check at run time.
I've tried with persistent_state set to 0 and 1 with no effect.
Thanks!
-------------
Jim DeVito
_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users