Hi,

I guess does not answer the guestion but take a look at this:

https://github.com/OpenSIPS/opensips/issues/2076

that said could you setup b2b logic to fix interworking issues?

Tomi

On 18. Jan 2021, at 18.31, solarmon <[email protected]> wrote:


Hi Johan,

The first 183 packet that is received has no SDP in it and has:

Require: 100rel

I wish to prevent this from being passed on, but still respond what with a 
PRACK (since 100rel has been requested). The reason for this is that our system 
will not work if it first receives a 183 without SDP and then receives a second 
183 with SDP.

Thank you.

On Mon, 18 Jan 2021 at 16:13, Johan De Clercq <[email protected]> wrote:
> you mean that the remote party sends you required:100rel ? The only way that 
> I know is by using b2b logic. 
> Maybe Bogdan can shed some light here. 
> 
> Op ma 18 jan. 2021 om 17:07 schreef solarmon <[email protected]>:
>> Hi,,
>> 
>> I have a requirement to stop 183 without SDP packets from being passed, as 
>> well as having to reply back with a PRACK.
>> 
>> I can stop the 183 without SDP from being passed on with the following in 
>> onreply_route[]
>> 
>>  if ($rs == "183" && !has_body_part("application/sdp")) {
>>                 drop();
>>                 exit;
>>         }
>> 
>> However, how do I reply back with a PRACK?
>> 
>> Thank you.
>> _______________________________________________
>> Users mailing list
>> [email protected]
>> http://lists.opensips.org/cgi-bin/mailman/listinfo/users
> _______________________________________________
> Users mailing list
> [email protected]
> http://lists.opensips.org/cgi-bin/mailman/listinfo/users
_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users
_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users

Reply via email to