:+1:

no lookup for sequential, just loose_route().  Again, you should do nothing special for REFER. If the BYE's work for you, the REFER should also.

Regards,

Bogdan-Andrei Iancu

OpenSIPS Founder and Developer
  https://www.opensips-solutions.com
  https://www.siphub.com

On 10/24/23 7:02 AM, Carlos Eduardo wrote:
It fails because you're sending a sequential request to another endpoint. As it doesn't have the dialog there, it will fail.

You should route the REFER as any other sequential request and then the other UA will handle it and transfer.

Em seg., 23 de out. de 2023 às 12:02, nutxase via Users <[email protected] <mailto:[email protected]>> escreveu:

    So when using a webrtc client with mid_registrar it seems the
    transfer does nothing
    but if i put something like this

    if ( has_totag() && is_method("REFER") ) {
    mid_registrar_lookup("location","i","$tu:5060");
    t_relay();
                    exit;
            }
    then a call transfers but doesnt drop the transferer's call


    Sent with Proton Mail <https://proton.me/> secure email.

    ------- Original Message -------
    On Monday, October 23rd, 2023 at 3:39 PM, Bogdan-Andrei Iancu
    <[email protected] <mailto:[email protected]>> wrote:

    Hi,

    The REFER is an in-dialog request like any other (re-INVITE and
    BYE), so no special handling. What transfer scenario are you
    currently failing ?

    Regards,
    Bogdan-Andrei Iancu

    OpenSIPS Founder and Developer
       https://www.opensips-solutions.com  <https://www.opensips-solutions.com>
       https://www.siphub.com  <https://www.siphub.com>
    On 10/16/23 5:49 PM, nutxase via Users wrote:
    Hi All

    I am using opensips as a mid_registrar for webrtc and everything
    is working fine except call transfers, as i understand they use
    refer, is there anything specific i need to change to get them
    to work?
    if you can point me to a module id appreciate it



    Sent with Proton Mail <https://proton.me/> secure email.

    _______________________________________________
    Users mailing list
    [email protected]  <mailto:[email protected]>
    http://lists.opensips.org/cgi-bin/mailman/listinfo/users  
<http://lists.opensips.org/cgi-bin/mailman/listinfo/users>


    _______________________________________________
    Users mailing list
    [email protected] <mailto:[email protected]>
    http://lists.opensips.org/cgi-bin/mailman/listinfo/users
    <http://lists.opensips.org/cgi-bin/mailman/listinfo/users>



--
*Carlos E. Wagner*
/Tecnólogo em Telecomunicações, Opensips Certified Professional/****

*
*Fone:*+55 48 99981-0894
*
*E-mail:*[email protected] <mailto:[email protected]>_
_
*LinkedIn:* https://www.linkedin.com/in/carlos-eduardo-wagner-96bbb433/ <https://www.linkedin.com/in/carlos-eduardo-wagner-96bbb433/>

_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users

_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users

Reply via email to