Dear PWscf Developer and Users:
I am using QHA code to calculate thermodynamic properties for highly-ordered 
doping cubic system, such like:
ibrav = 1 ,
ATOMIC_POSITION crystal
  A  0.0  0.0  0.0
  B  0.0  0.5  0.5
  B  0.5  0.0  0.5
  B  0.5  0.5  0.0
  C  0.5  0.0  0.0
  C  0.0  0.5  0.0
  C  0.0  0.0  0.5
  C  0.5  0.5  0.5
When I checked the files named projected_DOS.Xi, except the PDOS of Xi atom 
itself, gx, gy and gz are also listed in the last three columns.
At beginning, I thought gx, gy and gz must represent the vibrations on x,y,z 
directions, respectively. However, I found the values of gx, gy and gz are 
significantly different with each other, especially for the atom with different 
kinds elements as nearest neighbor atoms.
Since my model is cubic and with high symmetry, the vibration in x,y,z 
directions should be same. So I think they may not mean the vibrations on 
x,y,z's direction.
Then, would any one like to tell me the meaning of them? I am really puzzled by 
this data~~~
Thanks.


--
GAO Zhe
CMC Lab, MSE, SNU, Seoul, S.Korea
-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
http://www.democritos.it/pipermail/pw_forum/attachments/20110807/c5dcc6e3/attachment.htm
 