On Monday 14 March 2005 23:55, Nitya Nath wrote: > In FM case, I should expect some net moment in cell but I am getting > zero magnetic moment. Why is it happening?
either you did not break the symmetry with a starting ferromagnetic polarization (see variable "starting_magnetization") or your system doesn't like to be in a ferromagnetic state P. -- Paolo Giannozzi e-mail: giannozz at nest.sns.it Scuola Normale Superiore Phone: +39/050-509876, Fax:-563513 Piazza dei Cavalieri 7 I-56126 Pisa, Italy