On Jul 25, 2012, at 16:13 , William Parker wrote: > Each image will output to its own output file labeled out.i_0 where > i runs from 1 to N_image - 1. The frequencies in these files will > be garbage unless all of the representations for a particular q- > point are contained in one image. After you run the image- > parallelized run, you must copy the data-file.*.*.xml files (not > the data-file.*.xml files) to the _ph0/(prefix).phsave/ directory > and run again on one image with recover=.true. in your input file. > This will produce the correct frequencies in the output file and > the (prefix).dyn* files.
funny: "image" parallelization (the one done with MPI, not with separate calculations on a grid) should automatically perform the final step of collecting results. P. --- Paolo Giannozzi, Dept of Chemistry&Physics&Environment, Univ. Udine, via delle Scienze 208, 33100 Udine, Italy Phone +39-0432-558216, fax +39-0432-558222