On Apr 2, 2010, at 22:44 , jia chen wrote: > Since QE4.0, empty states feature in CP code didn't work anymore.
it works in a different way: you can use the charge density produced using CP to start a conventional non-selfconsistent calculation P. --- Paolo Giannozzi, Dept of Physics, University of Udine via delle Scienze 208, 33100 Udine, Italy Phone +39-0432-558216, fax +39-0432-558222