Dear all,

I'm trying to optimize a relatively large system such as 2 C60 / unit cell. So 
i start with relatively large cell dimensions. I'm doing vc-relax calculations 
with either 'damp'&'damp-pr' or 'bfgs'&'bfgs' for ionic and cell dynamics 
options. However, after some number (~50-70) of successful  (ionic/cell) steps 
the calculations crash with the error: 

     Error in routine scale_h (1):
     Not enough space allocated for radial FFT: try restarting with a larger 
cell_factor.

It seems like this happens when the size of the simulation cell changes by some 
notable amount with respect to the starting one. Perhaps, the program 
automatically changes the plane wave basis set (increases). If i restart the 
calculations with the latest (most optimal) configuration of the system and the 
same amount of memory allocated, the further optimization can proceed some more 
time (also ~50 - 70 steps) before next crash. So in principle it is still 
possible to achieve the convergence with this sequence of operations, but it is 
quite inconvenient to reset the calculations every 50-70 steps. 

So my question: is there any way to avoid this and get optimized results 
without intermediate crashes (apart from increasing the amount of memory 
reserved in the beginning)? 

Thank you,
Alexey


-- 
Dr. Alexey V. Akimov

Postdoctoral Research Associate
Department of Chemistry
University of Rochester

aakimov at z.rochester.edu 

Reply via email to