Dear bamidele ibrahim:
It is up to you to set the reference level for a semiconductor as long as
within the gap, as prof. Baroni said. In addition, the reference energy is only
used by plotband.x when generating *.ps file, not used when generating *.xmgr
file. I think the *.xmgr file is more useful for further plotting. Thus, it is
unnecessary to pay much attention to the so called "Fermi energy".
Best Wishes!
Yours Sincerely
L. F. Huang
> Date: Fri, 10 Jun 2011 07:52:59 +0200
> From: Stefano Baroni
> Subject: Re: [Pw_forum] how to get fermi energy for semiconductor in
> pwscf calculation
> I do not know what plotband uses the Fermi energy for, but have you tried to
> just give any energy within the gap? (which you have) Probably any other
> value would also do, but just a little trial-and-error has never harmed
> anybody ...
> Also, it would be nice if you were to uveil your identity, affiliatio, etc.
> when posting to this mailing list.
> Regards - SB
>
------
======================================================================
L.F.Huang(???) DFT and phonon physics
======================================================================
Add: Research Laboratory for Computational Materials Sciences,
Instutue of Solid State Physics,the Chinese Academy of Sciences,
P.O.Box 1129, Hefei 230031, P.R.China
Tel: 86-551-5591464-326(office)
Fax: 86-551-5591434
Our group URL: http://theory.issp.ac.cn
Scientific blog: http://blog.sciencenet.cn/home.php?mod=space&uid=345795
======================================================================
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
http://www.democritos.it/pipermail/pw_forum/attachments/20110610/8ed58b0a/attachment.htm