On Jul 21, 2008, at 16:12 , Padmaja Patnaik wrote: > This warning messages continues for around 4 /5 days
the cpu time per k-point for a DOS calculation will be similar to the cpu time per kpoint of a scf calculation. If you want a DOS with many k-points, it will take a lot of time. > and then either it stops the calculation or it writes all the > expected output files but the DOS curve obtained is wrong. how do you know it is wrong? Paolo --- Paolo Giannozzi, Dept of Physics, University of Udine via delle Scienze 208, 33100 Udine, Italy Phone +39-0432-558216, fax +39-0432-558222