On Fri, 06 Mar 2009 18:13:29 +0100, idoldog <idoldog at gmail.com> wrote:
> I want to know where my mistakes are and how to solve them.

In order to compute the DOS, dos.x uses, per default, the same kind of smearing 
used in the SCF calculation; if it is MV or MP, it can deal some small negative 
DOS. Conversely, projwfc.x uses, per default, the simple gaussian smearing, 
which cannot produce negative DOS.

Have a check at your input files, and see if you are using the different 
smearing choices consistently.

cheers

-- 
Lorenzo Paulatto
SISSA  &  DEMOCRITOS (Trieste)
phone: +39 040 3787 511
skype: paulatz
www:   http://people.sissa.it/~paulatto/

     *** save italian brains ***
 http://saveitalianbrains.wordpress.com/

Reply via email to