Hi, Lex,

When I specify the atomic positions in terms of the crystal basis vectors
I get the wrong distribution of atoms (as seen e.g. in xcrysden). But if I
consider the basis vectors to be those I have pointed out the
configuration is OK.

Have you noticed something in this line?

Thanks,

 Andr? Saraiva
 PhD Student @  Koiller - Capaz Group
 Universidade Federal do Rio de Janeiro
 Instituto de F?sica
 +55 21 25627343
 also at if.ufrj.br

> Hi Andre,
>
> I've used the bct unit vectors and believe the results to be okay. Could
> you point out specifically what problem you found?
>
> Thanks,
>
> Lex Kemper
> Department of Physics and QTP
> University of Florida
>
> Andre Saraiva wrote:
>> Dear developers,
>>
>> I have noticed what I believe to be an error in the user guide for
>> PWSCF. In the section "Input Data Description", the basis vectors for
>> the Body Centered Tetragonal Bravais Lattice are strange. I believe the
>> correct expression for v1 would be
>>
>> v1 = (a/2)(-1,1,c/a).
>>
>> Using the expression given in the user guide leads to errors in the
>> crystal structure. The corrected expression seems to work just fine. I
>> don't know if I can change the user guide myself or if it is alowed only
>> for developers.
>>
>> Regards,
>>
>> Andr? Saraiva
>> PhD Student @  Koiller - Capaz Group
>> Universidade Federal do Rio de Janeiro
>> Instituto de F?sica
>> +55 21 25627343
>> also at if.ufrj.br
>>
>>
>> _______________________________________________
>> Pw_forum mailing list
>> Pw_forum at pwscf.org
>> http://www.democritos.it/mailman/listinfo/pw_forum
>
>

Reply via email to