If [...] the code stops at the first namelist (``control'') and you are running on a PC cluster: your communication library (MPI) might not be properly configured to allow input redirection (so that you are effectively reading an empty file). See section "Running on parallel machines'', or inquire with your local computer wizard (if any).
In the section "Running on parallel machines'' you find: Some implementations of the MPI library may have problems with input redirection in parallel. If this happens, use the option -in (or -inp or -input), followed by the input file name. Example: pw.x -in input -npool 4 > output. Paolo -- Paolo Giannozzi e-mail: giannozz at nest.sns.it Scuola Normale Superiore Phone: +39/050-509876, Fax:-563513 Piazza dei Cavalieri 7 I-56126 Pisa, Italy _______________________________________________ Pw_forum mailing list Pw_forum at pwscf.org http://www.democritos.it/mailman/listinfo/pw_forum