Dear Lorenzo, Thank you very much for your replay.
As you told if i include the two options in my input file/script file can i get the values up to 0.08. Thanking you ... On Fri, Jan 3, 2014 at 11:05 PM, Lorenzo Paulatto < lorenzo.paulatto at impmc.upmc.fr> wrote: > Dear Param, > the electron phonon calculation does not use the vale of sigma from the > electronic caculation, but a series of values that you specify in the > phonon input. > > I'm not sure if these variables are documented, if they are not, use e.g.: > > el_ph_sigma=0.01, > el_ph_nsigma=50, > > Which means 50 values of smearing from 0.01Ry to 50*0.01 Ry = 0.5 Ry > > > cheers > -- > Dr. Lorenzo Paulatto > IdR @ IMPMC -- CNRS & Universit? Paris 6 > phone:+33 (0)1 44275 084 / skype: paulatz > www: http://www-int.impmc.upmc.fr/~paulatto/ > mail: 23-24/4?16 Bo?te courrier 115, 4 place Jussieu 75252 Paris C?dex 5 > _______________________________________________ > Pw_forum mailing list > Pw_forum at pwscf.org > http://pwscf.org/mailman/listinfo/pw_forum > -------------- next part -------------- An HTML attachment was scrubbed... URL: http://pwscf.org/pipermail/pw_forum/attachments/20140104/9a2b374c/attachment.html