If after the first 10, max 20 steps or so, the value of the "estimated scf accuracy" does not show any sign of decreasing, something nasty is happening. There is no point in insisting with more iteractions: either input data is wrong, or the system cannot find a sensible ground state for the structure it has, with the constraints you are (implicitly) imposing. Since I do not see anything obviously wrong in your data, the second case is likely the correct one. Your system, containing magnetic atoms, highly correlated electrons, an oxygen vacancy, seems to me a good candidate as multiple source of trouble