I did several simulation using both input_dft='dft+d2' and input_dft='dft+ts', but of course separately.

I misunderstood the use of vdW semiempirical correction. I am self-taught.

Sorry

Thank you very much Paolo

always patient with me !! :)



Il 08/07/2015 17:24, Paolo Giannozzi ha scritto:


On Wed, Jul 8, 2015 at 6:02 PM, Francesco Pelizza <[email protected] <mailto:[email protected]>> wrote:


    I am wondering if when you want to use the input_dft='dft+d2'
    input_dft='dft+ts'


did you really wrote in input  " input_dft='dft+d2' " or 'dft+ts'? then
1) you shouldn't: input_dft should be used only to set van der Waals non-local functionals; all other cases (semiempirical van der Waals corrections) are sety using variable "vdw_corr". 2) you shouldn't use an old version of the code (newer ones check for nonexistent DFT)

Paolo



--
Paolo Giannozzi, Dept. Chemistry&Physics&Environment,
Univ. Udine, via delle Scienze 208, 33100 Udine, Italy
Phone +39-0432-558216 <tel:%2B39-0432-558216>, fax +39-0432-558222 <tel:%2B39-0432-558222>


_______________________________________________
Pw_forum mailing list
[email protected]
http://pwscf.org/mailman/listinfo/pw_forum

_______________________________________________
Pw_forum mailing list
[email protected]
http://pwscf.org/mailman/listinfo/pw_forum

Reply via email to