I have tried to run a geometry optimisation on a 2D water slab using VDW-DF 
exchange functional, dipole correction, etc., etc.

I find that by starting from different initial states, I can end up with two 
equivalent supercells, one of which has a rectangular basis, and the other has 
a parallelogram as base (angle about 60 degrees). The total energies after 
minimisation agree to 7 decimal places. So far so good. The in-plane stresses 
are very different, however: the rectangular one is 2.7 GPa, and the 
parallelogram one is 2.2 GPa (both in plane stresses are equal as one would 
expect).

Is there any reason why that should be the case? Anyone aware of any pitfalls 
with the calculation of stresses in the vdW part of the code? I am using QE 
5.1.2.

Niels

---
Prof. Niels R. Walet                             Phone:  +44(0)1613063693
School of Physics and Astronomy         Fax:    +44(0)1613064303
The University of Manchester               Mobile: +44(0)7516622121
Manchester, M13 9PL,  UK                  room 7.7, Schuster Building
email: [email protected]
web:   
http://www.theory.physics.manchester.ac.uk/~mccsnrw<../../owa/redir.aspx?C=8f9098c1943846dcba17536b8618a38a&URL=http%3a%2f%2fwww.theory.physics.manchester.ac.uk%2f%7emccsnrw>
_______________________________________________
Pw_forum mailing list
[email protected]
http://pwscf.org/mailman/listinfo/pw_forum

Reply via email to