You simply cannot get 2 pico second trajectory in 10 steps! Your timestep may 
at most be 1fs.
 
 Huiqun Zhou


------------------ Original ------------------
From:  "Narendranath Ghosh"<[email protected]>;
Date:  Fri, Jul 22, 2016 02:17 AM
To:  "pw_forum"<[email protected]>; 

Subject:  [Pw_forum]  MD trajectories in NVE and NVT condition

 
Dear all               After successfully optimize a system (CNT+Fullerene) 
with 424 no of carbon atoms, I am trying to get a 2 pico-second  trajectory  
using Andersen thermostat.


          What actually indicate that my system is achieved in equilibrium with 
the desired temperature (T=300 K)


          As my system is very large Could I allowed to get 2 picosecond 
trajectory in 10 steps with 200fs in each steps.In this circumstances what will 
be my input geometry  in the next steps.


          Is this last geometry of the 1st run will be the input geometry of 
the 2nd run and so on. Or something else.


          In QE which flags  allowed one to get trajectories in NVE condition. 






           Please suggest a solution... 
    



Narendra Nath Ghosh

Research Associate

University of Gour Banga

Malda-732102

India
_______________________________________________
Pw_forum mailing list
[email protected]
http://pwscf.org/mailman/listinfo/pw_forum

Reply via email to