Hi QE users, I was wondering why is it required to have ATOMIC_POSITIONS and CELL_PARAMETERS in cp.x input file using restart. I have a cp.x input file with restart=‘reset_counters' which shows segmentation fault if I don’t include atomic positions and cell parameters. They are read from the restart file anyway and this also shows up in output file: positions will be re-read from restart file.
Thanks, Zeeshan -- Zeeshan Ahmad PhD student, Mechanical Engineering Carnegie Mellon University email: [email protected] <mailto:[email protected]> http://www.andrew.cmu.edu/~azeeshan/ <http://www.andrew.cmu.edu/user/azeeshan/>
_______________________________________________ Pw_forum mailing list [email protected] http://pwscf.org/mailman/listinfo/pw_forum