Dear AT Raji,

A sample input file will help clarifying the issue.

My guess is that you are dealing with a system with complex potential
energy landscape and multiple local minima.  If you know that the total
magnetization has to be zero and you are using smearing, then try giving
small magentization as intial guess (start_magnetization). You can also
constrain the total magnetization by tot_magnetization =0.

Mostafa
AUC, New Cairo, Egypt