Hi, Please, for those working in the ACE implementation. I tried to restart a non-gamma-only hybrid calculation with QE-6.2 and using USPP PAW datasets (okvan and okpaw == .true.). However, the code crashes because when the subroutine rotate_becxx (PW/src/us_exx.f90) tries to access becxx0 and it has not been set yet. As commented in the code, the subroutine sum_bec (sum_band.f90) should be called before.
The point is that in the subroutine electrons (PW/src/electrons.f90), there is a first conditional that gears up everything for a restarting calculation before the self-consistent loop starts. And this is the part in which the code crashes, when the sequence of subroutines implemented in the file PW/src/exx.f90 is called: exxinit -> rotate_becxx. Whereas in a 'from_scratch' run, before that same call, in the self-consistent loop, the sequence of subroutines is called before: electrons_scf -> sum_band -> sum_bec -> store_becxx0, and everything is fine. Please, I'm trying to figure out whether it is possible to set becxx0 before start the self-consistent loop when restarting a hybrid calculation. If someone could help with a tip or with a sign that there is a possible solution in a next release, I will be very thankful. Maybe something could be done in the subroutines exxinit or aceinit, both implemented in PW/src/exx.f90. From the source code, it seems that things still the same in version 6.2.1. Thank you very much! Ary Ferreira FAPESP postdoctoral fellow UFSCar - Brazil -- http://lattes.cnpq.br/8221674673413336
_______________________________________________ users mailing list [email protected] https://lists.quantum-espresso.org/mailman/listinfo/users