Dear Siebe and Quantum Espresso friends,

According to me, the tag A in &SYSTEM has a different meaning.

See:

https://www.quantum-espresso.org/Doc/INPUT_PW.html#idm231


Met vriendelijke groeten,
Mit freundlichen Grüßen,
With kind regards,


Willem Offermans
Researcher Electrocatalysis SCT
VITO NV | Boeretang 200 | 2400 Mol
Phone:+32(0)14335263 Mobile:+32(0)492182073

[email protected]<mailto:[email protected]>

[cid:[email protected]]

On 8 Oct 2019, at 17:07, Siebe Vanlommel 
<[email protected]<mailto:[email protected]>> wrote:

Hi all,

I am trying to figure out whether there is a way to scale all three unit cell 
vectors at once in QE using pw.x. In my input file, I am using the 
CELL_PARAMETERS card (in units of Angstrom) to specify a unit cell. This 
(https://www.mail-archive.com/[email protected]/msg19387.html) 
old post seems to suggest that the 'A' parameter in the &SYSTEM section acts as 
a scaling parameter if 'ibrav==0' and the CELL_PARAMETERS card is used to 
specify the lattice. I take this to mean that each lattice vector is multiplied 
by *A, where A is a dimensionless number. However, QE complains that:
"Error in routine cell_base_init (2):
     lattice parameter specified twice"

I've tried specifying the atomic positions in 'crystal' (fractional) 
coordinates and in Angstroms but to no use. Input file is attached below. I'm 
using QE version 6.4.1.

Is the interpretation of A as a scaling parameter with these settings 
deprecated, or am I missing something?

Thanks in advance,
Siebe

input file:

 &CONTROL
                       title = 'cha' ,
                 calculation = 'scf' ,
                  wf_collect = .true. ,
               etot_conv_thr = 1.0D-6 ,
 /
 &SYSTEM
                       ibrav = 0,
                           A = 1.2,
                         nat = 108,
                        ntyp = 2,
                     ecutwfc = 100 ,
                       nosym = .true. ,
 /
 &ELECTRONS
           scf_must_converge = .true. ,
 /
CELL_PARAMETERS angstrom
    13.738516409   -0.000070574    0.000007978
    -6.869319180   11.897869408   -0.000009602
     0.000010055   -0.000007302   14.715552482
ATOMIC_SPECIES
    O   15.99940  O.pbe-rrkjus.UPF
   Si   28.08551  Si.pbe-rrkj.UPF
ATOMIC_POSITIONS crystal
O     0.901932010         0.098069851         0.126854702
O     0.098068745         0.901933544         0.873144107
O     0.901940529         0.803877937         0.126862649
O     0.098062465         0.196127742         0.873139246
(...)
K_POINTS gamma
_______________________________________________
Quantum ESPRESSO is supported by MaX 
(www.max-centre.eu/quantum-espresso<http://www.max-centre.eu/quantum-espresso>)
users mailing list 
[email protected]<mailto:[email protected]>
https://lists.quantum-espresso.org/mailman/listinfo/users

Indien u VITO Mol bezoekt, hou aub er dan rekening mee dat de hoofdingang 
voortaan enkel bereikbaar is vanuit de richting Dessel-Retie, niet vanuit 
richting Mol, zie vito.be/route.<http://www.vito.be/route>
If you plan to visit VITO at Mol, then please note that the main entrance can 
only be reached coming from Dessel-Retie and no longer coming from Mol, see 
vito.be/en/contact/locations.<http://www.vito.be/en/contact/locations>
VITO Disclaimer: http://www.vito.be/e-maildisclaimer
_______________________________________________
Quantum ESPRESSO is supported by MaX (www.max-centre.eu/quantum-espresso)
users mailing list [email protected]
https://lists.quantum-espresso.org/mailman/listinfo/users

Reply via email to