Dear Singaravelan
nscf or band calculations must be strictly performed *after* scf calculations, using the very same scf potential and calculating with this potential the eigenvalues at whatever k-point, requiring less computational resources than scf calculations. Intrinsically, there is no strict convergence criterion. Of course it would be pointless to perform a nscf calculation with less or the very same k-points of the scf calculation, but the exact number of nscf k-points actually used depend on the purpose of the nscf calculation (eg, band structure, stm imaging, calculation of DOS, input of a following GW calculation, transport calculation, ...). In this regard, you should verify the desired convergence of the property you are interested in with respect to the k-points.
HTH
Giuseppe



singaravelan T R <[email protected]> ha scritto:

Dear all,
Let I am performing calculation for silicon.
 I performed convergence test for no.of k points with the scf calculation
and found that no. of k points as 4 4 4 0 0 0.
*Question:For nscf calculation the no. of k points has to be doubled or not
?. That is: 8 8 8 0 0 0.*
For nscf calculation too, if we need to optimize the no. of k points , then
there is no point in optimization of k points for scf calculation. We can
straight away optimize the k points in nscf calculation itself.
Because to my knowledge all the convergence and optimization has to be
performed with self consistent field (scf) calculation. After optimization
only we do nscf calculation.
With thanks,
Singaravelan T R



GIUSEPPE MATTIOLI
CNR - ISTITUTO DI STRUTTURA DELLA MATERIA
Via Salaria Km 29,300 - C.P. 10
I-00015 - Monterotondo Scalo (RM)
Mob (*preferred*) +39 373 7305625
Tel + 39 06 90672342 - Fax +39 06 90672316
E-mail: <[email protected]>

_______________________________________________
Quantum ESPRESSO is supported by MaX (www.max-centre.eu/quantum-espresso)
users mailing list [email protected]
https://lists.quantum-espresso.org/mailman/listinfo/users

Reply via email to