Dear Stephen Zhang

crystal_b for positions is meaningless, it is used only for specifying K-POINTS  paths in band structure calculations, that's why the program gets confused and uses Bohrs.

Please have a look to the documentation here

https://www.quantum-espresso.org/Doc/INPUT_PW.html#idm1064

for the possible modes to write atomic positions in the input

best wishes

Pietro



On 11/07/20 20:42, Stephen Zhang wrote:
Hi Everyone,

I am currently running relaxation computations with quantum Espresso,
and I am unsure what the units are for the {crystal_b} configuration
when determining the positions of the atoms, below is my input. I am
assuming that celldm(1) is in angstrom, however on xcrysden, it says
that these units are in Bohr. Can anyone provide some clarification on
this?
Thanks

&control
     calculation = 'vc-relax'
     prefix = 'CoSnS'
     outdir = './outdir'
     pseudo_dir = '/home/stephen/qe-6.5/SSSP_precision_pseudos'
     etot_conv_thr = 1e-5
     forc_conv_thr = 1e-4
/
&system
     ibrav=5, celldm(1) =5.381186316302011, celldm(4) = 0.4980629252775897,
     nat=7, ntyp=3,
     ecutwfc=70
     occupations='smearing',smearing='gaussian',degauss=0.01
/
&electrons
     conv_thr=1e-8
/
&ions
/
&cell
     cell_dofree='ibrav'
/
ATOMIC_SPECIES
  Co  58.933195 Co.pbe-spn-kjpaw_psl.0.3.1.UPF
  Sn  118.71 Sn.pbe-dn-kjpaw_psl.1.0.0.UPF
  S  32.065 S.pbe-n-kjpaw_psl.1.0.0.UPF
ATOMIC_POSITIONS {crystal_b}
  Co 0.5000 0.0000 0.0000
  Co 0.0000 0.5000 0.0000
  Co 0.0000 0.0000 0.5000
  Sn 0.5000 0.5000 0.5000
  Sn 0.0000 0.0000 0.0000
  S 0.7195 0.7195 0.7195
  S 0.2805 0.2805 0.2805
K_POINTS (automatic)
   4 4 4 0 0 0


_______________________________________________
Quantum ESPRESSO is supported by MaX (www.max-centre.eu/quantum-espresso)
users mailing list [email protected]
https://lists.quantum-espresso.org/mailman/listinfo/users