Hi 

It seems that the program reads the uncollected format with davcio. 
Hopefully it is  sufficient you set disk_io=’high’ and the uncollected files 
will be written and kept after the run.

Hope this helps 
Pietro  

Sent from Mail for Windows 10

From: Dario Baratella
Sent: Thursday, March 18, 2021 6:28 PM
To: [email protected]
Subject: [QE-users] QE-GPU and KGEC

Dear all,

I'm trying to calculate the conductivity tensor by using the KGEC software 
included in the qe package. I know that the KGEC code is compatible with qe 
until the 6.1 version and for this version the qe code was still using the old 
file format to save the wavefunctions.

My problem is that I need to use qe-gpu for the scf calculation (for efficiency 
reasons). As far as I know there is no way to compile qe-gpu to make it save 
the wavefunctions in the old file format. My question is if someone knows a 
code that can turn the new file format  into the old one. I tried to do a brief 
research on the web but i didn't find anything.

Thank you so much for your answers.


Dario Baratella
Phd student
University of Milano-Bicocca
Department of Material Science


_______________________________________________
Quantum ESPRESSO is supported by MaX (www.max-centre.eu)
users mailing list [email protected]
https://lists.quantum-espresso.org/mailman/listinfo/users

Reply via email to