Dear all,
Useoccupations=from_input' for a single k-point to fix occupation,Why does the self-consistent calculation not converge? Without spinning, I took out 0.02 electrons from VBM to the CBM for more than 600 electron systems. ------- Related Parameter Settings: occupations = 'from_input' OCCUPATIONS 2.0000 2.0000 2.0000 2.0000 2.0000 2.0000 2.0000 2.0000 ... 2.0000 2.0000 2.0000 1.9800 0.0200 0.0000 0.0000 0.0000 -------------- Zhi-Guo TAO Dept. of Physics, Fudan University 2205 Songhu Rd., Yangpu District Shanghai, 200438, China
_______________________________________________ Quantum ESPRESSO is supported by MaX (www.max-centre.eu) users mailing list [email protected] https://lists.quantum-espresso.org/mailman/listinfo/users