Dear Experts,

Hi and Happy New Year.



I am experiencing that using Nose thermostat in cp.x is somehow fails to 
control T and I have a large deviations from the target T even using fnosep 
in the midway of natural ionic frequencies.

On the other hand, "rescaling" is quite successful.

Which point should I take care in order to have successful results with 
Nose. I had also used chain to respect ergodicity.

Any comments is highly appreciated.



Best regards,

Mahmoud



---------------------------------------

Mahmoud Payami

NSTRI, AEOI, Tehran, Iran


Email: [email protected]
Phone: +98 (0)21 82066504
--------------------------------------------------------
_______________________________________________
Quantum ESPRESSO is supported by MaX (www.max-centre.eu)
users mailing list [email protected]
https://lists.quantum-espresso.org/mailman/listinfo/users

Reply via email to