Dear all.
I am doing a hybrid calculation of bands in the description HSE. My system
is a layer of carbon of 12 atoms at the unit cell. Part of the input is:
!***********************************************
&system
ibrav = 8
celldm(1) = 9.354145
celldm(2) = 1.412121
celldm(3) = 2.020202
nat = 12
ntyp= 1
nbnd = 28
occupations = 'smearing'
smearing = 'gauss'
degauss = 0.01d0
ecutwfc = 80.d0,
ecutrho = 320.d0,
input_dft='HSE'
nqx1=2, nqx2=2, nqx3=1
/
&electrons
mixing_mode = 'plain'
mixing_beta = 0.5
conv_thr = 1.0d-8
/
ATOMIC_SPECIES
C 12.0107 C_ONCV_PBE_sr.upf
ATOMIC_POSITIONS {angstrom}
C -2.4782021033 0.0532472376 0.0000000000
C -0.0032466468 -0.0074780911 0.0000000000
C -1.2248455699 0.7566921174 0.0000000000
C 1.2184243008 0.7566745164 0.0000000000
C -0.7508000863 2.0875939495 0.0000000000
C 0.7444458380 2.0876025878 0.0000000000
C -0.7508209917 3.5285256632 0.0000000000
C 0.7444436433 3.5285398124 0.0000000000
C -1.2248187534 4.8594363132 0.0000000000
C 1.2184363447 4.8594795502 0.0000000000
C -0.0032200034 5.6235974470 0.0000000000
C -2.4781959721 5.5628888962 0.0000000000
K_POINTS (automatic)
9 6 1 0 0 0
ADDITIONAL_K_POINTS tpiba_b
6
0.0 0.0 0.0 20
0.5 0.0 0.0 10
0.5 0.3540 0.0 20
0.0 0.0 0.0 10
0.0 0.3540 0.0 20
0.5 0.3540 0.0 0
!***********************************************
And when I tried to run, it did not finish the calculation. I was reading
about that in the QE-Forum and some advice suggested that my problem would
be about memory, So I divided my calculation. Now I am doing the same
calculation but I exchange the "ADDITIONAL_K_POINTS" section by:
ADDITIONAL_K_POINTS crystal_b
1
0.4400000000 0.4400000000 0.0000000000 0
So I calculated the bands point by point and then matched the results. This
worked for different kpoints, except for the k-points which are between the
corner of Brillouin Zone and Gamman (along the diagonal path, for example
0.4400000000 0.4400000000 0.0000000000). In these points I received
the following message:
total energy = -136.45081412 Ry
estimated scf accuracy < 6.8E-09 Ry
smearing contrib. (-TS) = -0.00080694 Ry
internal energy E=F+TS = -136.45000718 Ry
convergence has been achieved in 10 iterations
Using ACE for calculation of exact exchange
EXX grid: 225657 G-vectors FFT dimensions: ( 54, 75, 108)
ACE projected onto 28 (nbndproj) and applied to 28 (nbnd) bands
ZPOTRF exited with INFO= 1
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
Error in routine ZPOTRF (1):
Cholesky failed in invchol.
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
stopping ...
I do not know what the problem is. Maybe some of us can give some advice.
The pseudo potential is PBE Norm Conserving.
Thank you for your attention.
_______________________________________________
The Quantum ESPRESSO community stands by the Ukrainian
people and expresses its concerns about the devastating
effects that the Russian military offensive has on their
country and on the free and peaceful scientific, cultural,
and economic cooperation amongst peoples
_______________________________________________
Quantum ESPRESSO is supported by MaX (www.max-centre.eu)
users mailing list [email protected]