Hello everyone,
I am doing NVT MD calculations using pw.x code. During the simulation, my
pressure was constantly oscillating at a particular value of around 50 GPa.
Many literature review papers* mention this line: "The supercell **volume
was relaxed in such a way to minimize the system's energy." In principle,
during the simulations, one could adjust the supercell volume to make the
external pressure of the inherent **structures equal to zero." I* have
tried a lot of different things to maintain my pressure at zero, but as
soon as I manage to achieve oscillatory zero pressure, some other
parameters seem to shift. For example, I ran "md" at 3000K using the
rescaling method, then restarted and ran "vc-relax" with fixed ion
positions to achieve lower pressure, as shown below.
" total stress (Ry/bohr**3) (kbar) P=
123.26
total stress (Ry/bohr**3) (kbar) P=
116.29
total stress (Ry/bohr**3) (kbar) P=
89.51
total stress (Ry/bohr**3) (kbar) P=
77.12
total stress (Ry/bohr**3) (kbar) P=
60.67
total stress (Ry/bohr**3) (kbar) P=
55.80 "
However, in the same vc-relax output*,** temperature* moved as follows:
" Ekin = 0.00000000 Ry T = 0.0 K Etot = -13138.95318083
Ekin = 0.30599294 Ry T = 253.6 K Etot = -13138.94891345
Ekin = 1.41097581 Ry T = 714.8 K Etot = -13138.96700552
Ekin = 1.65432345 Ry T = 878.9 K Etot = -13139.19284122
Ekin = 1.87157146 Ry T = 1101.3 K Etot = -13139.61462781
Ekin = 1.67673049 Ry T = 1142.5 K Etot = -13140.01208055 "
Is this temperature gain due to electron kinetic energy or why does T begin
at zero? Is there something I am missing? Additionally, I used "vc-md" to
control the temperature and pressure, but after that, I was unable to
restart the file
My exact methodology is:
1. restart_mode ='from_scratch',----> MD calculation (NVT) at 1000K
with simple rescaling method up to 10 picoseconds
2. restart_mode = "restart"-----> 'vc-relax' up to pressure convergence
threshold (0.5d0 Kbar) !!! { problem: temperature not maintained shown
above}
My main question is:
Can I restart the calculation from MD to vc-md/relax and again from
vc-md/relax to md ?
And if I run vc-relax or vc-md calculations, my supercell volume fluctuates
slightly, requiring me to switch from an old supercell celldm to a new one
in order to maintain pressure zero..
regards
Jayraj Anadani
Ph.D Scholar, SPU
_______________________________________________
The Quantum ESPRESSO community stands by the Ukrainian
people and expresses its concerns about the devastating
effects that the Russian military offensive has on their
country and on the free and peaceful scientific, cultural,
and economic cooperation amongst peoples
_______________________________________________
Quantum ESPRESSO is supported by MaX (www.max-centre.eu)
users mailing list [email protected]
https://lists.quantum-espresso.org/mailman/listinfo/users