----- Original Message -----
> From: "Oved Ourfali" <oourf...@redhat.com>
> To: "Nathanaël Blanchet" <blanc...@abes.fr>
> Cc: users@ovirt.org, "Eli Mesika" <emes...@redhat.com>
> Sent: Monday, February 2, 2015 7:04:05 PM
> Subject: Re: [ovirt-users] power management test fails while ipmi command     
> successes
> 
> We've recently pushed a patch to have lanplus as a default option for drac7.
> Until then you can set this option explicitly through the additional options
> in the power management configuration tab in the edit/add host dialog.
> Please check whether it helps.
> 
> CC-ing Eli, just in case I've missed something.

Please make sure that you have the following in the UI options field (on the 
Edit dialog PM TAB) 

privlvl=OPERATOR,lanplus,delay=10


> 
> Regards,
> Oved
> 
> On Feb 2, 2015 6:10 PM, Nathanaël Blanchet <blanc...@abes.fr> wrote:
> >
> > Hi all,
> >
> > I've just installed two new dell r630 hosts and every thing is alright
> > with vdsm registration, but power management test always fails with ipmi
> > or drac7 item. When I start the manual ipmi command like this "ipmitool
> > -I lanplus -H 10.34.20.45 -U root chassis power status", it always
> > success with "power chassis is on".
> > All of my other dell servers (r710, r620) success on power management test.
> > Is it a known bug?
> > _______________________________________________
> > Users mailing list
> > Users@ovirt.org
> > http://lists.ovirt.org/mailman/listinfo/users
> 
_______________________________________________
Users mailing list
Users@ovirt.org
http://lists.ovirt.org/mailman/listinfo/users

Reply via email to