----- Original Message ----- > From: "Oved Ourfali" <oourf...@redhat.com> > To: "Nathanaël Blanchet" <blanc...@abes.fr> > Cc: users@ovirt.org, "Eli Mesika" <emes...@redhat.com> > Sent: Monday, February 2, 2015 7:04:05 PM > Subject: Re: [ovirt-users] power management test fails while ipmi command > successes > > We've recently pushed a patch to have lanplus as a default option for drac7. > Until then you can set this option explicitly through the additional options > in the power management configuration tab in the edit/add host dialog. > Please check whether it helps. > > CC-ing Eli, just in case I've missed something.
Please make sure that you have the following in the UI options field (on the Edit dialog PM TAB) privlvl=OPERATOR,lanplus,delay=10 > > Regards, > Oved > > On Feb 2, 2015 6:10 PM, Nathanaël Blanchet <blanc...@abes.fr> wrote: > > > > Hi all, > > > > I've just installed two new dell r630 hosts and every thing is alright > > with vdsm registration, but power management test always fails with ipmi > > or drac7 item. When I start the manual ipmi command like this "ipmitool > > -I lanplus -H 10.34.20.45 -U root chassis power status", it always > > success with "power chassis is on". > > All of my other dell servers (r710, r620) success on power management test. > > Is it a known bug? > > _______________________________________________ > > Users mailing list > > Users@ovirt.org > > http://lists.ovirt.org/mailman/listinfo/users > _______________________________________________ Users mailing list Users@ovirt.org http://lists.ovirt.org/mailman/listinfo/users