Hi, I see sanlock lease refresh issues before your reboots: Mar 30 17:21:12 hype01 sanlock[1210]: 2017-03-30 17:21:12+0300 2109 [3805]: s1 delta_renew read timeout 10 sec offset 0 /dev/463e6284-7676-432e-9eed-384587525846/ids Mar 30 17:21:12 hype01 sanlock[1210]: 2017-03-30 17:21:12+0300 2109 [3805]: s1 renewal error -202 delta_length 10 last_success 2079
Can you please share also your sanlock logs? On Fri, Mar 31, 2017 at 2:23 PM, George Mcro <[email protected]> wrote: > Hello, > > My infrastructure consist of 2 ovirt-nodes and one ovirt-engine. All of > them use Centos 7. > > I have already configured Ovirt-Engine and both of ovirt-nodes. Before I > install the two ovirt-nodes in Ovirt engine, I install this repo in both of > them à yum install http://resources.ovirt.org/ > pub/yum-repo/ovirt-release41.rpm. > > I want to clarify that the ovirt engine is HP proliant DL380 G6 and the 2 > ovirt nodes are HP Proliant DL380G7. Also, the ovirt-node servers are > hardware identical(same motherboard, same HP model, same NIC’s etc). > > Now, the issue. > > Ovirt-Node no2(hype02) operates perfectly for days with 4 VM’s on it. But, > when I am migrating vm’s from ovirt-Node no2 (hype02) to ovirt-Node no1 > (hype01) to see if it is capable to operate like hype02, it restarts after > couple of hours (2-4). > > > > Ovirt engine event logs report : > > VDSM hype01 command GetStatsVDS failed: Heartbeat exceeded (hype01). > > Or > > VDSM hype01 command GetStatsVDS failed: Connection issue > java.rmi.ConnectException: Connection timeout > > > > I have done almost every change I could think of. I reinstall Centos 7 > couple of times, upgrade BIOS and iLO in the latest version. Moreover, I > changed Hard Drives (with the same HP Model), Motherboard, and RAMs but > nothing worked. > > > > Then, I tried something else. I put the server in Maintenance mode and > voila, it was operating for 4 days straight without restarting. > > > > So, I do not know what it’s wrong and logs sadly do not help me understand. > > I will post here some log files, dmesg, messages, supervdsm and vdsm. > > Any ideas what’s the issue here. Hardware or Software. Any help would be > appreciated. > > > King Regards, > > George Mcro > > _______________________________________________ > Users mailing list > [email protected] > http://lists.ovirt.org/mailman/listinfo/users > >
_______________________________________________ Users mailing list [email protected] http://lists.ovirt.org/mailman/listinfo/users