Hi all, I've got a brand new Unity300 that I'm trying to hook up to a 4.3 setup with iSCSI.
The way I have it organized is simple: - each hypervisor has two NICs set to 192.168.10.x and 192.168.20.x - the SAN has 4 ports on each controller (A and B), amounting to 8 portal IPs I can log into. The problem with the EMC is that at any time, only either A or B addresses would be active, so I can only login to 4 out of the 8 addresses, while the engine, in order to add all the possible target IQNs needs to log into all 8 of them. I've been trying to find a solution for a while now, EMC generally suggest I use powerpath (not an option here obviously). Did anyone set up one of these EMC boxes with oVirt before? Thanks
_______________________________________________ Users mailing list -- [email protected] To unsubscribe send an email to [email protected] Privacy Statement: https://www.ovirt.org/privacy-policy.html oVirt Code of Conduct: https://www.ovirt.org/community/about/community-guidelines/ List Archives: https://lists.ovirt.org/archives/list/[email protected]/message/OEWJWQQPL3CMWVBFVCAOOP4ZNG4WXXP5/