> Please clarify the topology in more details. What exactly is intended
> to run where?
The guess of the engine on one machine (ovirt-ctl) then the db, dwh dwh_db on
the separate machine (ovirt-net)
> On which machine?
This is on ovirt-net when trying to setup dwh+dwh_db
> This should only happen on the dwh machine ("ovirt-net"?)
Yes, has only happened during the DWH setup on ovirt-net
> A guess:
>
> Your setup (with the engine on one machine and its db+dwh+dwh_db on
> another) is not a common
> one, and was likely not tested with the addition of grafana
> integration (new in 4.4).
>
> So you can try this:
> 1. Setup DBs + engine (already done)
> 2. On engine-setup on the other machine, reply 'No' to 'Configure
> grafana?'. This should hopefully succeed.
> 3. Run there 'engine-setup --reconfigure-optional-components' and
> enable grafana. Hopefully will work this time...
Trying this; the initial setup for just dwh+dwh_db without grafana goes by
successfully now, however the reconfiguration setup run fails similarly as
before:
[ INFO ] Creating a user for Grafana
[ ERROR ] Failed to execute stage 'Misc configuration': terminating connection
due to administrator command
server closed the connection unexpectedly
This probably means the server terminated abnormally
before or while processing the request.
Thank you in advance,
Maitlin
_______________________________________________
Users mailing list -- [email protected]
To unsubscribe send an email to [email protected]
Privacy Statement: https://www.ovirt.org/privacy-policy.html
oVirt Code of Conduct:
https://www.ovirt.org/community/about/community-guidelines/
List Archives:
https://lists.ovirt.org/archives/list/[email protected]/message/JEAHPFRMIUIS3Z7MUBZFMLBBFX3HSDFN/