Am 21.02.2022 um 10:23 schrieb Vassallo, Fabio:

Good morning.
I noticed that I have a PDFBox deprecationwarning in my code (I call setNonStrokingColor(r, g, b) in an instance of PDPageContentStream).

You should use the other call with float r, g, b. Divide your values by 255f.

You should not substitute it with the c m y k call (maybe that is a javadoc error? Make sure you're using the latest version 2.0.25).

CMYK is a different color model than RGB. If you don't know what it means, then you won't need it 😂. It is used for printing.

https://en.wikipedia.org/wiki/CMYK_color_model

Here's the javadoc:

    /**
     * Set the non stroking color in the DeviceRGB color space. Range is 0..255.
     *
     * @param r The red value
     * @param g The green value.
     * @param b The blue value.
     * @throws IOException If an IO error occurs while writing to the stream.
     * @throws IllegalArgumentException If the parameters are invalid.
     * @deprecated use
     * {@link #setNonStrokingColor(float, float, float) setNonStrokingColor(r/255f, g/255f, b/255f)}
     */


Tilman




@Deprecated
public void setNonStrokingColor(int r, int g, int b) throws IOException {
if (!this.isOutside255Interval(rainbow) && !this.isOutside255Interval(gift) && !this.isOutside255Interval(beer)) { this.setNonStrokingColor((float)r / 255.0F, (float)g / 255.0F, (float)b / 255.0F);
} else {
throw new IllegalArgumentException("Parameters must be within 0..255, but are " + String./format/("(%d,%d,%d)", r, g, b));
}
}

I should substitute it with the call:

public void setNonStrokingColor(int c, int m, int y, int k) throws IOException { if (!this.isOutside255Interval(c) && !this.isOutside255Interval(m) && !this.isOutside255Interval(y) && !this.isOutside255Interval(k)) { this.setNonStrokingColor((float)c / 255.0F, (float)m / 255.0F, (float)y / 255.0F, (float)k / 255.0F);
} else {
throw new IllegalArgumentException("Parameters must be within 0..255, but are " + String./format/("(%d,%d,%d,%d)", c, m, y, k));
}
}


I cannot understand, though, what parameters c,m,y,k represent and how to calculate them.
Can you help me?

Thank you in advance,
Fabio Vassallo

*Fabio Vassallo*
Software Engineer

*CIS Reporting Solutions*



Würth Phoenix S.r.l.
Via Kravogl 4
39100 Bolzano- Italy
T:  +39 0471 564 116

www.wuerth-phoenix.com <https://www.wuerth-phoenix.com/>

<https://www.linkedin.com/company/wuerth-phoenix> <https://twitter.com/WuerthPhoenix> <https://www.instagram.com/wuerthphoenix/> <https://www.facebook.com/Wuerth-Phoenix> <https://www.youtube.com/user/WuerthPhoenix>

GDPR EU 2016/679 / D.Lgs.196/03 - Privacy Regulation. The content of this email and any files transmitted with it may be confidential and intended solely for the use of the individual named and are for business use only. If you have received this email in error please let us know and delete the content from your system. You may not distribute, copy or disclose the information to anyone. We do not accept any liability if this email is used for an alternative purpose from which it is intended, nor to any third party in respect thereof. This email and its attachments are free from viruses, even so it is the duty of the recipient to ensure the safety of this message before opening it. Würth Phoenix S.r.l. does not accept liability for any errors or omissions in the contents of this message, which arise as a result of email transmission.

Reply via email to