On Mon, Jun 25, 2018 at 4:19 AM, Rob Godfrey <[email protected]> wrote: > Hi Olivier, > > On Mon, 25 Jun 2018 at 09:40, VERMEULEN Olivier <[email protected]> > wrote: > >> Ok so I must keep a persistent config store for the Broker. >> But if I'm not mistaken the Dispacth-Router only supports a non-persistent >> config store. >> So are there any plans to implement new config stores for the >> dispatch-router? >> >> > Updated the subject in the hopes that someone more familiar with the > current and future capabilities of Dispatch can answer your questions. > > -- Rob
Thanks Rob, Olivier is correct. The configuration for Dispatch can be fully captured in a configuration file. However, changes made to the configuration via the management protocol are not persistent. The router has no means for generating a configuration file based on its current configuration. I would be interested in gathering requirements for persistent configuration for Qpid Dispatch Router. This is something that I've given a bit of thought to. It should be noted that the Enmasse project (Messaging as a Service in Kubernetes/OpenShift) addresses this in a limited way. I believe a persistent configuration solution for Qpid Dispatch Router should provide the following: - Synchronization of configuration across a set of routers in a network; - Multi-tenant isolation (i.e. configuration access/storage separated by tenant/vhost); -Ted > > >> Thanks, >> Olivier >> >> -----Original Message----- >> From: Rob Godfrey <[email protected]> >> Sent: vendredi 22 juin 2018 13:20 >> To: [email protected] >> Cc: Keith Wall <[email protected]> >> Subject: Re: [Broker-J 7.0.3] Memory configuration store and messages >> recovery >> >> Sure - but at that point you really need to provide the vhost config >> before the vhost itself starts up... would providing all the config >> (including the queue UUIDs) in a virtualHostInitialConfiguration provided >> to the VirtualHostNode on creation help I wonder... >> >> -- Rob >> >> On Fri, 22 Jun 2018 at 12:14, VERMEULEN Olivier < >> [email protected]> >> wrote: >> >> > Hello Rob, >> > >> > The main problem is to keep my version of the config in sync with the >> > one of each broker. >> > And knowing that all our brokers have the same config the added >> > complexity seems a bit overkill. >> > Especially when you start thinking about broker restart, scale up, >> > scale down... >> > >> > Olivier >> > >> > -----Original Message----- >> > From: Rob Godfrey <[email protected]> >> > Sent: vendredi 22 juin 2018 11:27 >> > To: [email protected] >> > Cc: Keith Wall <[email protected]> >> > Subject: Re: [Broker-J 7.0.3] Memory configuration store and messages >> > recovery >> > >> > In general, in order to be able to recover the queues from a message >> > store, the broker needs to know details of the queue - not only its >> > name, but also the type of the queue (standard, priority, LVQ, etc) as >> > well as other queue properties... this is precisely the data which is >> > stored in the configuration store, I don't think there's really any >> > way around that problem. What sort of problems are you experiencing >> > by using a non-Memory configuration store in your setup? >> > >> > -- Rob >> > >> > On Fri, 22 Jun 2018 at 10:47, VERMEULEN Olivier < >> > [email protected]> >> > wrote: >> > >> > > Hello Keith, >> > > >> > > Thanks for the quick answer. >> > > Our target is a cluster of brokers and dispatch-routers. >> > > To configure it we created a management component that centralizes >> > > the configuration of all the Qpid components. >> > > With this approach, having the broker store its own configuration is >> > > redundant with what our management component does and causes some >> > problems. >> > > That's why I was looking into the memory configuration store which >> > > would have made the broker behave like the dispatch-router regarding >> > > dynamic configuration. >> > > >> > > Olivier >> > > >> > > -----Original Message----- >> > > From: Keith W <[email protected]> >> > > Sent: vendredi 22 juin 2018 10:14 >> > > To: [email protected] >> > > Subject: Re: [Broker-J 7.0.3] Memory configuration store and >> > > messages recovery >> > > >> > > Hello Olivier >> > > >> > > Let me say first that the memory store's primary use-case is to aid >> > > development and testing of Broker-J, by speeding ups the test cycle. >> > > It also has utility when using embedding Broker-J in the unit tests >> > > of another project and you want to discard all messaging state >> > > between >> > tests. >> > > >> > > You are correct in your analysis. Queues (like all other objects) >> > > are allocated a random UUID on creation. This UUID is stored in the >> > > configuration store together with the queue's name and all other >> > > attributes. Within the message store, the message instance records >> > > refer to the queue's UUID rather than its name. So if your set-up >> > > is a persistent message store and volatile configuration store, yes, >> > > you will lose messages. This is expected. The recovery phase of >> > > startup will clear the message store of the orphans. >> > > >> > > What problem are you actually trying to solve? >> > > >> > > Keith. >> > > >> > > >> > > >> > > On 22 June 2018 at 08:54, VERMEULEN Olivier >> > > <[email protected]> >> > > wrote: >> > > > Hello, >> > > > >> > > > I was running some tests on a Java Broker with 'Memory' >> > > > configuration >> > > store and 'DERBY' message store. >> > > > Is there a way with this configuration to recover the messages >> > > > stored in >> > > DB upon a broker restart? >> > > > Because it looks like the messages are mapped to the queue UUID >> > > > and that >> > > they are discarded directly during the broker startup if the queue >> > > with the specified UUID is not found. >> > > > And obviously since I'm using a 'Memory' configuration store, the >> > > > queue >> > > has not been recreated yet when the broker starts... >> > > > Have I missed something? >> > > > >> > > > Thanks, >> > > > Olivier >> > > > ******************************* >> > > > >> > > > This e-mail contains information for the intended recipient only. >> > > > It may >> > > contain proprietary material or confidential information. If you are >> > > not the intended recipient you are not authorised to distribute, >> > > copy or use this e-mail or any attachment to it. Murex cannot >> > > guarantee that it is virus free and accepts no responsibility for >> > > any loss or damage arising from its use. If you have received this >> > > e-mail in error please notify immediately the sender and delete the >> > > original email received, any attachments and all copies from your >> system. >> > > >> > > -------------------------------------------------------------------- >> > > - To unsubscribe, e-mail: [email protected] For >> > > additional commands, e-mail: [email protected] >> > > >> > > ******************************* >> > > >> > > This e-mail contains information for the intended recipient only. It >> > > may contain proprietary material or confidential information. If you >> > > are not the intended recipient you are not authorised to distribute, >> > > copy or use this e-mail or any attachment to it. Murex cannot >> > > guarantee that it is virus free and accepts no responsibility for >> > > any loss or damage arising from its use. If you have received this >> > > e-mail in error please notify immediately the sender and delete the >> > > original email received, any attachments and all copies from your >> system. >> > > >> > > -------------------------------------------------------------------- >> > > - To unsubscribe, e-mail: [email protected] For >> > > additional commands, e-mail: [email protected] >> > > >> > > >> > ******************************* >> > >> > This e-mail contains information for the intended recipient only. It >> > may contain proprietary material or confidential information. If you >> > are not the intended recipient you are not authorised to distribute, >> > copy or use this e-mail or any attachment to it. Murex cannot >> > guarantee that it is virus free and accepts no responsibility for any >> > loss or damage arising from its use. If you have received this e-mail >> > in error please notify immediately the sender and delete the original >> > email received, any attachments and all copies from your system. >> > >> ******************************* >> >> This e-mail contains information for the intended recipient only. It may >> contain proprietary material or confidential information. If you are not >> the intended recipient you are not authorised to distribute, copy or use >> this e-mail or any attachment to it. Murex cannot guarantee that it is >> virus free and accepts no responsibility for any loss or damage arising >> from its use. If you have received this e-mail in error please notify >> immediately the sender and delete the original email received, any >> attachments and all copies from your system. >> --------------------------------------------------------------------- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected]