Hi Philipp,

We also tried with a vanilla version of the 0.91.0 stable and had no luck.
We are creating our own, Data Sources, yes, but the problem we have is only 
with the Compose and the Synchronize Streams, which shows only the stream of 
data of which we selected the timestamp but seems to be working if we create a 
datasource using the machine simulator adapter.
On the other hand, most of the default components work with our "custom" data 
sources.
To give you more context our data is composed of a timestamp field, and a value 
field.
The custom adapter that creates this data sources is based on the Http Stream 
adapter.

Best,

Federico.


Federico Rullo
_________________________________________________________________

GFT Italia S.r.l.
Via A. Rimassa, 51/2
16129 Genova, Italy

T +39 025 8158169
[email protected]
www.gft.com/it<http://www.gft.com/it>
https://blog.gft.com
https://www.linkedin.com/company/gft-group/
www.twitter.com/gft_it <http://www.twitter.com/gft_it>

Registered office: GFT Italia S.r.l., Via Sile 18, 20139 Milan (Italy)
VAT Code and number of registration with the Companies' Register of Milan: 
00819200478
Corporate capital: Euro 1,000,000 fully paid-in

Company subject to the direction and coordination activity of GFT Technologies 
SE

Ai sensi del Regolamento UE 2016/679 (GDPR) e delle Linee Guida per posta 
elettronica ed Internet del Garante Privacy si rende noto che le informazioni 
contenute nella presente comunicazione e i relativi allegati possono essere 
riservate e sono, comunque, destinate esclusivamente alle persone o alla 
Società sopraindicati. Le stesse non sono da considerarsi comunicazioni 
personali, quindi eventuali risposte potranno essere conosciute da persone 
appartenenti all'azienda.

In accordance with Regulation EU 2016/679 (General Data Protection Regulation) 
and Guidelines Applying to the Use of E-Mails and the Internet in the 
Employment Context of Italian Data Protection Authority it is announced that 
the information in this communication (which includes any documents with it) is 
confidential and meant only for above-mentioned persons and/or Companies; the 
information is not personal therefore, It is intended for the addressee only 
and any replies will be known by people belonging to the company.
_________________________________________________________________

[cid:signature-cloud_e31f4244-bb3f-4ff4-be4f-552f04b8a5ac.png]<https://www.gft.com/it/it/solutions/SOLUTIONS/it/IT-Metaverso>
From: Philipp Zehnder <[email protected]>
Sent: martedì 25 aprile 2023 16:01
To: [email protected]
Subject: AW: Compose Issue


[EXTERNAL EMAIL]
This email originated from outside of the organization or was sent 
unauthenticated. Do not click links or open attachments unless you confirm the 
sender and know the content is safe.
Hi Federico,

sorry as far as I know the problem this is not a known issue.

Maybe you can try it with the newest version 0.91.0.
If I understand it correctly you implemented your own components that produce 
the input for the compose processor, right?
Maybe you can check if there is a problem with the output events from your 
component.

Cheers,
Philipp

Von: Rullo, Federico <[email protected]<mailto:[email protected]>>
Datum: Mittwoch, 19. April 2023 um 16:35
An: [email protected]<mailto:[email protected]> 
<[email protected]<mailto:[email protected]>>
Betreff: Compose Issue
Hello,

When we use the "compose" component to aggregate data, it does not output all 
data from the stream where the timestamp was not selected but returns all data 
from the stream with the selected timestamp.
We also tried to aggregate our data with the "synchronize two streams" 
component,
but it does not output any our data even though it consumes the data.

Moreover, when we use these components with two streams ad hoc from the machine 
data simulator, they work well.

Do you know if this is a know issue? Can you give us more information about it?

We are currently running on the version 0.70.0, because of an issue with 
version 0.90.0.

Best,

Federico.

Federico Rullo
_________________________________________________________________

GFT Italia S.r.l.
Via A. Rimassa, 51/2
16129 Genova, Italy

T +39 025 8158169
[email protected]<mailto:[email protected]>
www.gft.com/it<http://www.gft.com/it>
https://blog.gft.com<https://blog.gft.com/>
https://www.linkedin.com/company/gft-group/
www.twitter.com/gft_it <http://www.twitter.com/gft_it%20>

Registered office: GFT Italia S.r.l., Via Sile 18, 20139 Milan (Italy)
VAT Code and number of registration with the Companies' Register of Milan: 
00819200478
Corporate capital: Euro 1,000,000 fully paid-in

Company subject to the direction and coordination activity of GFT Technologies 
SE

Ai sensi del Regolamento UE 2016/679 (GDPR) e delle Linee Guida per posta 
elettronica ed Internet del Garante Privacy si rende noto che le informazioni 
contenute nella presente comunicazione e i relativi allegati possono essere 
riservate e sono, comunque, destinate esclusivamente alle persone o alla 
Società sopraindicati. Le stesse non sono da considerarsi comunicazioni 
personali, quindi eventuali risposte potranno essere conosciute da persone 
appartenenti all'azienda.

In accordance with Regulation EU 2016/679 (General Data Protection Regulation) 
and Guidelines Applying to the Use of E-Mails and the Internet in the 
Employment Context of Italian Data Protection Authority it is announced that 
the information in this communication (which includes any documents with it) is 
confidential and meant only for above-mentioned persons and/or Companies; the 
information is not personal therefore, It is intended for the addressee only 
and any replies will be known by people belonging to the company.
_________________________________________________________________

[cid:[email protected]]

Reply via email to