As a general comment -- There's no need to manipulate the nbytes every time you 
write to the output. 
If you call the initial TSVConnWrite with INT64_MAX, you just need to set the 
nbytes to the final amount once (So the vconn will know to send you a 
WRITE_COMPLETE when it reaches this amount).

If you know the real payload size before setting up the vconn, just call 
TSVConnWrite with the real size and save yourself the hassle of adjusting the 
NBytes....

      Cheers,
                Uri

From: [email protected]
To: [email protected]
Date: Fri, 15 Mar 2013 11:13:33 -0700
Subject: Re: API Question


Shaun,
Thanks to your input I was able to identify the source of the problem.
In my main handle transformation method I was declaring a local variable  
int64_t nBytesWritten = 0;
Then depending on what state I was in I was calling the appropriate handler sub 
method.  Each of the sub methods returns the number of bytes written to the 
output by that method and I was aggregating those values via
nBytesWritten += subMethodCall(…);
At the end of my handle transformation method I was calling:if (nBytesWritten > 
0) {
                /* Modify the output
                 * VIO to reflect how much data the output connection should
                 * expect. This allows the output connection to know when it
                 * is done reading. We then reenable the output connection so
                 * that it can consume the data we just gave it.
                 */
                TSVIONBytesSet(data->output_vio, nBytesWritten);
                TSVIOReenable(data->output_vio);
}

At any rate this was working for small payloads but when the method was 
re-entered nBytesWritten was being re-initialized to 0 and then incremented.  
So the key is knowing that the value of nBytesWritten must be accumulated 
across invocations of the transformation handler.
by making this value part of the transaction data, I am able to preserve it 
across the invocations and the modified code:if (data->nBytesWritten > 0) {     
           /* Modify the output                 * VIO to reflect how much data 
the output connection should                 * expect. This allows the output 
connection to know when it                 * is done reading. We then reenable 
the output connection so                 * that it can consume the data we just 
gave it.                 */                TSVIONBytesSet(data->output_vio, 
data->nBytesWritten);                TSVIOReenable(data->output_vio);}
I am worried though about what you said regarding it getting confused and 
sending a WRITE_COMPLETE event pre-maturely.  Right now with my current test 
cases seem to be working as expected but then again, it all seems like voodoo 
and black magic under the ATS hood and I don't know that there isn't a test 
case which would break this.  I wish I could be more confident that the code I 
am writing is going to work as intended under all cases.  
For the moment however everything seems to work.  I am logging the values of 
the output nbytes and ndone.  And it would seem that ndone is not getting 
incremented at all during the multiple invocations of my transform handler.  
Ideally what I would like to do is to have the down stream output handler 
consume data as soon as it gets it from my transform, but not to stop or 
terminate until I have finished sending ALL of my data downstream but I am 
afraid to breathe on the code at this point until I find a breaking case which 
will mandate a change.
Thank you for your help, you have truly made my day.
Steve Owens

From:  Shaun mcginnity <[email protected]>
Reply-To:  "[email protected]" <[email protected]>
Date:  Fri, 15 Mar 2013 10:35:01 -0700
To:  "[email protected]" <[email protected]>
Subject:  Re: API Question

Yes, it allows the VIO to know when it is done. We only set it when we have 
read all the data from the input. I suspect if you continually set it the VIO 
might think it is done and send a WRITE_COMPLETE but you actually still have 
more to write.

Shaun


On Fri, Mar 15, 2013 at 5:20 PM, Owens, Steve <[email protected]> wrote:
Shaun,
Looking at the code for TSVIONBytesSet we havevoid281TSVIONBytesSet(TSVIO viop, 
int64_t nbytes)
282{
283  sdk_assert(sdk_sanity_check_iocore_structure(viop) == TS_SUCCESS);
284  sdk_assert(nbytes >= 0);
285286  VIO *vio = (VIO *)viop;
287  vio->nbytes = nbytes;
288}It looks like this method updates the nbytes of the VIO.  But it doesn't 
explain what the implications of changing this value are.  I am presuming that 
when I called TSVConnWrite(output_conn, contp, data->output_reader, INT64_MAX); 
 That the value of vio->nbytes got set to INT64_MAX.  Since my transform may or 
may not know how much upstream data it needs to process I don't see any way for 
it to update this value to anything meaningful and it makes me wonder why I 
would want to.In my STATE_EXIT processing I am calling: 
TSContCall(TSVIOContGet(input_vio), TS_EVENT_VCONN_WRITE_COMPLETE, input_vio); 
But I don't call: TSVConnShutdown(TSTransformOutputVConnGet(contp), 0, 1); 
until I receive the TS_EVENT_VCONN_WRITE_COMPLETE event in my 
callbackHandler.What would happen if I continuously update 
TSVIONBytesSet(output_vio, total_written) to indicate how much I have written 
thus far?Steve Owens

From:  Shaun mcginnity <[email protected]>
Reply-To:  "[email protected]" <[email protected]>
Date:  Fri, 15 Mar 2013 09:48:05 -0700
To:  "[email protected]" <[email protected]>
Subject:  Re: API Question

Hi Steve,

I believe that in a transform you should only call TSVConnWrite once.

You say you are shutting down the VIOs. Are you doing this when you 
receive a WRITE_COMPLETE event? If not you may be closing the VIO early. You 
can tell the output VIO that all the data has been written to it using 
TSVIONBytesSet(output_vio, total_written);

Regards,

Shaun


On Fri, Mar 15, 2013 at 4:25 PM, Owens, Steve <[email protected]> wrote:
Shaun,
This is extremely helpful.  In fact it would make a great addition to the 
traffic server on line documentation.  Personally I prefer to understand what 
the methods I am calling do rather than not.
The one question that remains unanswered is whether or not this method needs to 
be called more than once.  
The reason for my question is this:
I have a transform which essentially prepends and postpends content to the 
upstream content being served.  It works in states 
        STATE_START = write the prefix content downstream and shift to 
STATE_MIDDLE.        STATE_MIDDLE = copy upstream content to downstream until 
there is no more content and then shift to STATE_END.        STATE_END = write 
the suffix content downstream and shift to STATE_EXIT.        STATE_EXIT = 
clean up the transaction and shut down the VIO's because were done.        This 
plugin works with smaller upstream content as expected.  However when the 
upstream content gets larger than about 30K, what I am seeing is that from the 
transform plugin's perspective it is working as expected.  The expected amount 
of data is being copied downstream and the suffix is being written.  I can tell 
this because I am logging the values of upstream_avail, upstream_todo, 
bytesWritten etc.  And everything adds up to all content being delivered.  
However the client is receiving truncated content and I am baffled as to why 
this my be happening.  I thought that maybe I was not properly using the 
TSVConnWrite method but from your explanation of the method below, it would 
seem that this is possibly not the case.
At any rate,
Thank you for the explanation.
Best Regards,
Steve Owens
From:  Shaun mcginnity <[email protected]>
Reply-To:  "[email protected]" <[email protected]>
Date:  Fri, 15 Mar 2013 07:09:12 -0700
To:  "[email protected]" <[email protected]>
Subject:  Re: API Question

Hi Steve,TSVConnWrite initiates a write operation on the
transform's downstream VConnection. The last parameter is the total amount of
data you are going to write. INT64_MAX is effectively unlimited.When you have 
data to write you get the VIO's buffer
(TSVIOBufferGet(output_vio)), and copy the data into it. Then the VIO is
reenabled. Reenabling the VIO causes an IMMEDIATE event to be sent to the VIO's
VConnection. When the VConnection's event handler has finished with the data it
will call your continuation back. If it expects you to send more data it will
pass a WRITE_READY event. If you have given the VIO the total amount of data as
set in TSVConnWrite it will call you back with a WRITE_COMPLETE event. 
Thisbehaviour is the same as what the transform should do to its input VIO. 

Since the downstream VConnection is the client and / or
cache, if you do a finite write, i.e. not INT64_MAX, then the HTTP transaction
will close when the limit is reached. Issuing another write in this case will
probably not work. You can do multiple writes on a NetVConnection though, e.g.
as provided by TSNetConnect.Hope that helps. 

Shaun -----Original Message-----From: James Peach [mailto:[email protected]] 
Sent: Friday, March 15, 2013 3:12 AMTo: [email protected]: 
Re: API Question On 14/03/2013, at 5:13 PM, "Owens, Steve" 
<[email protected]> wrote: > In looking at the following documentation: 
http://trafficserver.apache.org/docs/trunk/sdk/io-guide/transformations.en.html>
 > It would seem that the only mention of TSVConnWrite
is to a single parameter method.> > Yet in my plugin I am using > > 
data->output_vio = TSVConnWrite(output_conn,
contp, data->output_reader,>                                 INT64_MAX);> > 
What has changed about this method?> > What does it actually do? 

It schedules data to be written to the VConnection. > > Do I need to call it 
every time the plugin is
re-enabled?  Or can I just call it once? I don't know that I really understand 
the question, but
if the length is INT64_MAX you would only call it once. If you want you cancall 
it a multiple times with shorter lengths. J

                                          

Reply via email to