Dear Carleton,

I think you will be interested in this train story at 
http://www.cahsrblog.com/2010/12/hsr-emissions-paper-was-wrong/?utm_source=rss&utm_medium=rss&utm_campaign=hsr-emissions-paper-was-wrong
 where they say:

Berkeley’s numbers are undone by a simple unit conversion error committed by a 
CHSRA consultant. Conversions between metric and imperial units are prone to 
errors and misunderstandings, most famously in the case of NASA’s $300 million 
Mars Climate Orbiter mission, which was inadvertently crashed into Mars because 
of an overlooked conversion between pounds and Newtons. In the case of the 
high-speed rail study, the CHSRA consultant’s unit conversion error leads to an 
overestimate of HSR energy consumption by a factor of nearly four–not just in 
the Berkeley study, but also in the CHSRA’s program level environmental reports.

The energy consumption figure cited in the Berkeley study and its supplementary 
data is 170 kilowatt-hours per vehicle kilometer traveled, or kWh/VKT, a 
measure of how much energy a high-speed train consumes on average when 
traveling one kilometer. This number is correctly converted by Berkeley from a 
figure of 924,384 BTU/VMT referenced in the energy chapter of the 2008 CHSRA 
program-level EIR. That chapter in turn references a peer-review study 
performed for CHSRA by the German firm DE-Consult in 2000, which evaluated the 
energy consumption of a hypothetical 16-car trainset with a seating capacity of 
1200 and a design speed of 385 km/h (240 mph) and an operating speed of 350 
km/h (220 mph), essentially a souped-up German ICE3. The DE-Consult study 
(unavailable online) contains detailed performance simulations for the proposed 
California system that give the average energy consumption of such a train as 
74.2 kWh/VMT, or 46 kWh/VKT (see copy of Annex 4-11). And therein lies the 
error: CHSRA’s consultant botched the conversion from kilowatt-hours to British 
Thermal Units, feeding Berkeley a figure of 170 kWh/VKT instead of 46 kWh/VKT.

I wonder why they were converting from British Thermal Units (no temperature 
specified) to kilowatt hours instead of (say) megajoules per kilometre (MJ/km). 
Clearly none of the consultant engineers has any sort of firm grasp on 
metrology -- VKT for vehicle kilometre travelled doesn't impress me as coming 
from a knowledgeable person who knows his SI from his toothbrush.

Cheers,

Pat Naughtin LCAMS
Author of the ebook, Metrication Leaders Guide, see 
http://metricationmatters.com/MetricationLeadersGuideInfo.html
Hear Pat speak at: http://www.youtube.com/watch?v=_lshRAPvPZY 
PO Box 305 Belmont 3216,
Geelong, Australia
Phone: 61 3 5241 2008

Metric system consultant, writer, and speaker, Pat Naughtin, has helped 
thousands of people and hundreds of companies upgrade to the modern metric 
system smoothly, quickly, and so economically that they now save thousands each 
year when buying, processing, or selling for their businesses. Pat provides 
services and resources for many different trades, crafts, and professions for 
commercial, industrial and government metrication leaders in Asia, Europe, and 
in the USA. Pat's clients include the Australian Government, Google, NASA, 
NIST, and the metric associations of Canada, the UK, and the USA. See 
http://www.metricationmatters.com for more metrication information, contact Pat 
at [email protected] or to get the free 'Metrication matters' 
newsletter go to: http://www.metricationmatters.com/newsletter to subscribe.