Hey Jason, All blocks have to have at least 1 input and 1 output port. You are correct that you should still setup an input port in Noc Script, but not expose it in the GRC XML. Take a look at the Siggen block's HDL, Noc Script, and GRC XML.
Jonathon On Thu, Jul 13, 2017 at 12:15 PM, Jason Matusiak via USRP-users < usrp-users@lists.ettus.com> wrote: > I have a block that I want to essentially be a source block in RFNoC > (outputting data from a ROM), but when I go to probe, I get this error: > RuntimeError: LookupError: Path not found in tree: > /mboards/0/xbar/dataGenerator_0/ports/in > > Is this because I set it up without sink input? Is there any way around > it? I think the solution is to put a sink in the rfnoc/blocks/ XML file > but NOT the grc XML file, is that right? > > _______________________________________________ > USRP-users mailing list > USRP-users@lists.ettus.com > http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com >
_______________________________________________ USRP-users mailing list USRP-users@lists.ettus.com http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com