Altuğ,

per channel, there's 2 half-bands and 1 CIC. The rule is: We try and
enable as many half-bands as possible, the rest is done by CIC. So, any
ratio of sample_rate to master_clock_rate that is divisible by 4 has 2
half-bands, any other even ratio has 1 half-band, and the remainder is
done in the CIC.

Cheers,
Martin

On 07/18/2017 07:55 AM, altuğ kaya via USRP-users wrote:
> Hello everyone,
> 
> In B210 there are 2 half-band filters and 4 CIC filters. As far as I
> know we can select how many filters we would like to use by tuning the
> ratio between sample_rate and master_clock_rate. What is the rule of it?
> 
> I am looking forward to your answer,
> Altug Kaya
> 
> 
> _______________________________________________
> USRP-users mailing list
> USRP-users@lists.ettus.com
> http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com
> 


_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

Reply via email to