Altuğ, per channel, there's 2 half-bands and 1 CIC. The rule is: We try and enable as many half-bands as possible, the rest is done by CIC. So, any ratio of sample_rate to master_clock_rate that is divisible by 4 has 2 half-bands, any other even ratio has 1 half-band, and the remainder is done in the CIC.
Cheers, Martin On 07/18/2017 07:55 AM, altuğ kaya via USRP-users wrote: > Hello everyone, > > In B210 there are 2 half-band filters and 4 CIC filters. As far as I > know we can select how many filters we would like to use by tuning the > ratio between sample_rate and master_clock_rate. What is the rule of it? > > I am looking forward to your answer, > Altug Kaya > > > _______________________________________________ > USRP-users mailing list > USRP-users@lists.ettus.com > http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com > _______________________________________________ USRP-users mailing list USRP-users@lists.ettus.com http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com