Hi ben,
On Sat, 2018-03-24 at 05:32 +0000, Benny Alexandar wrote:
> on USRP N210 is 100 MHz / 2 = 50 MHz. Is that correct ? 
> Can USRP sample at such high rates ? 

Yes. But it's impossible to fit 50 MS/s · 32 b/S through a 1 Gb/s link,
so you need to reduce the sample depth to 8 b, so that a complex sample
only takes 16 b/S.

> 
> If I need a bandwidth of say 500kHz,  from USRP then I need to set N
> = 200, is my math correct
yes.

Best regards,
Marcus