On 11/19/2018 06:35 AM, Fabian Schwartau via USRP-users wrote:
Anyone? This is a quite annoying bug and I am having trouble working around it as I cannot meet my timing requirements.
I'm only about 50% certain that sample-rate setting is covered by timed commands. I'll talk to R&D and get back to you on this.



Am 20.07.2018 um 11:05 schrieb Fabian Schwartau via USRP-users:
Hello everyone,

I am experencing some issues when switching the sample rate.
I have two synchronized USRP X310 with a total of 4 TwinRX. I am doing timed commands to jump around in the spectrum with all receivers at the same frequency (SIMO stuff). I also need to switch sample rates in between. When I keep the sample rate constant, everything works fine, but once I switch it between two timed receptions, I get very strange errors. Like I get an end-of-frame after just a part of the samples I requested. It seems like it is not possible to time the sample rate switch command. Here is a debug output of my code which makes it quite clear what happens:

(1) Changed sample rate from 1e+07 to 5e+07
(2) Requested 32768 Samples
(3) Requested 32768 Samples
(4) Requested 32768 Samples
(5) Changed sample rate from 5e+07 to 1e+07
(6) Reading 32768 Samples
(7) Got only 6553 of 32768 samples at EOF

Commands 1-5 are transmitted to the USRP right away using its command buffer. Then my program starts reading the first requested 32768 but gets only 6553, which is precisely 1/5th of the requested samples. I guess this is because he switched sample rate to 1/5th right before executing the first stream command. But the sample rate switch is also timed and should be executed after the three stream commands.

I attached the part of the code which is responsible for sending the timed commands to the USRPs. This runs basically in a while(1) in a seperate thread, while there is a seconds thread receiving the data blocks, which produced the lines 6-7 of above output.

Is this a bug or feature I don't get? Are set_rx_rate commands not timed when using set_command_time? How can I solve this isse? I need very precise timing and also fast switching between frequencies and sample rates.

Best regards,
Fabian

_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com


_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com


_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

Reply via email to