Hi Diogo, While there are hooks in UHD to support custom reference clock rates, the majority of the synchronization (PPS and sample clock alignment) routines rely heavily on known rates (10, 20, 25M). It would be non-trivial to update everything to use 100M as reference. Let me know if this is a path you want to pursue and I could point you in the direction of the major refactoring areas.
-Daniel On Wed, Apr 24, 2019 at 5:04 AM Diogo Botelho Ribeiro Marinho via USRP-users <[email protected]> wrote: > Hello, > > Looking into schematic of N310 motherboard , I notice it accepts 10MHz > ,20MHz and 25MHz external clock. I need to synchronize the USRP N310 with > external PLL. Can i use 100 MHz clock as reference? > > Thanks in advanced > Diogo Marinho > > > _______________________________________________ > USRP-users mailing list > [email protected] > http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com > -- Daniel Jepson Digital Hardware Engineer National Instruments O: +1.512.683.6163 [email protected]
_______________________________________________ USRP-users mailing list [email protected] http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com