You cannot run your streaming ports through a switch like that, since the
host PC to switch link becomes a bottleneck...

Streaming ports should go to NICs directly on the host system. So, to
stream from two radios, each having a 10gig SFP link, the host would need
two 10gb interfaces plus an additional LAN interface for the
control/management network(sometimes this will even be OK if you are going
wifi to where the management port is plugged in)

On Thu, May 21, 2020 at 12:12 PM Farhan Naeem via USRP-users <
[email protected]> wrote:

> Hello,
>
> I am trying to understand how to connect two N310 devices to get a MIMO
> configuration.
>
> 1. I connect two of the SFP+ 10G Ethernet ports on each N310 device to a
> 10Gbit Ethernet switch. And connect the other end of this Ethernet switch
> to my host system.
> 2. I need additional 1Gb Ethernet switch to connect to the management
> Ethernet port of the N310 devices from my host system.
> 3. A common clock reference.
>
> I have attached a block diagram here. Thanks.
>
> Best Regards,
> Farhan
> _______________________________________________
> USRP-users mailing list
> [email protected]
> http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com
>
_______________________________________________
USRP-users mailing list
[email protected]
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com