You cannot run your streaming ports through a switch like that, since the host PC to switch link becomes a bottleneck...
Streaming ports should go to NICs directly on the host system. So, to stream from two radios, each having a 10gig SFP link, the host would need two 10gb interfaces plus an additional LAN interface for the control/management network(sometimes this will even be OK if you are going wifi to where the management port is plugged in) On Thu, May 21, 2020 at 12:12 PM Farhan Naeem via USRP-users < [email protected]> wrote: > Hello, > > I am trying to understand how to connect two N310 devices to get a MIMO > configuration. > > 1. I connect two of the SFP+ 10G Ethernet ports on each N310 device to a > 10Gbit Ethernet switch. And connect the other end of this Ethernet switch > to my host system. > 2. I need additional 1Gb Ethernet switch to connect to the management > Ethernet port of the N310 devices from my host system. > 3. A common clock reference. > > I have attached a block diagram here. Thanks. > > Best Regards, > Farhan > _______________________________________________ > USRP-users mailing list > [email protected] > http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com >
_______________________________________________ USRP-users mailing list [email protected] http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com