On 08/22/2020 09:08 PM, kp...@trilcomm.com wrote:
Yes relative delay between samples in buffer.
While detecting SYNC signal of 5G periodically, it detects gradually increased delay from its expected position. It means expected to receive at 2280 position of buffer but its keep detecting away from expected position, 2281,2282,2284,........ and so on.

Thanks,
Prasad.

My guess is that you have an off-by-one error in your buffer-harvesting code. This has nothing to do with the device.


_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com