It’s like the semantics of “pC clock” synch causing this. Try changing to 
“unknown PPS”

Sent from my iPhone

> On Mar 31, 2021, at 10:43 AM, Lorenzo Bertizzolo 
> <[email protected]> wrote:
> 
> 
> Hi all,
> 
> I am experiencing a time synchronization issue internal to the USRP X310. 
> With the help of an oscilloscope, I measured an (apparently) constant delay 
> between the two X310 output TX ports of approximately 10~14 µs (picture 
> attached). 
>  
> I tried different bandwidths, both UHD 4 (UHD 4.0.0.0-25-g1a34ba8a) and UHD 
> 3.15 (UHD 3.15.0.0-62-g7a3f1516), and different X310 hardware, always 
> experiencing the same time delay.
> 
> To track down this issue I simplified my flowgraph. It now feeds data to the 
> two UHD USRP sink channels from file, using `packet_len’ tags accordingly 
> (picture attached). 
> I verified thanks to the QT scope that the two streams enter the USRP Sink 
> with the two tags at the same time. 
> 
> Setup:USRP X310 / UBX daughterboards / Gnuradio 3.8 with UHD 4, Gnuradio 3.7 
> with UHD 15
> 
> 
> It seems that either the USRP sink block or UHD are not sending out the 
> samples at the same time from the two X310 TX daughterboards. 
> Is there any misconfiguration in my setting that could be the root cause of 
> this issue?
> 
> Thanks,
> Lorenzo
> <image001.png>